Fuji Electric 10 KVA Online UPS
Fuji Electric

Fuji Electric 10 KVA Online UPS- Transformer Model

NPR 249,999NPR 326,00023% off

Finch PG is a double conversion online ups with a power factor 0.9 providing higher quality power density, delivering 12.5% more power when compared with conventional UPS (designed with power factor of 0.8). Finch PG is with DSP Technology and active input power factor correction design to ensure better output voltage conditions, power quality and power performance at all times. Its dual mains input will secure the power reliability in areas with poor power quality.

Product Description

Features and Benefits

  • Online double conversion UPS.
  • Input power factor corrector 0.99 (PFC)
  • Automatic bypass, allow to transfer the load to the mains in case of overload or internal fault
  • Inbuilt Isolation Transformer (optional) provides a galvanic isolation between the mains and the loads
  • Hot standby Configuration to ensure the availability of Quality power to mission critical applications
  • Battery cold start feature allows UPS to be powered on from the battery without utility
  • Can be paralleled up to 3 Units for capacity and/ or redundancy
  • Flexible or settable battery configuration
  • Wide tolerance on the input voltage reduces switchovers to battery mode prolonging battery life.
  • Green and energy saving: AC/AC efficiency up to 98% in ECO mode

Product Specifications

A C Mode ( Efficiency)91.5%
Battery Numbers16 Nos.
Battery TypeSMF VRLA/ Vented Battery/ Lead Acid Battery
Battery Typical Recharge Time9 Hours Recover to 90% Capacity
Capacity9 Kw
CertificatesBIS, ISO 9001, ISO 14001, ISO 45001
ConfigurationThree Phase Input and Single Phase Output
Current Crest Ratio03:01 (max)
GeneralFinch PG
Height (mm)826
Humidity20-90 % RH @ 0-40°C (Non-Condensing)
IndicatorsLCD ( Load Level\, Battery Level\, AC Mode\, Battery Mode\, Bypass Mode and Fault Indicators)
Input Frequency Range46 Hz ~54 Hz or 56~64 Hz
Input Power Factor≥ 0.99 @ 100% load
Input Voltage Range190-520 VAC (3 Phase)at 50% Load & 305-478 VAC (3 Phase) at 100% Load
Input- Frequency46 ~ 54 Hz or 56 ~ 64 Hz
Input- Phase3 Phases + Neutral + Ground
Input- Voltage190-520 VAC (3-phase at 50% load) | 305-478 VAC (3-phase at 100% load)
L C D DisplayUPS Status, Load Level, Battery Level, Input/Output Voltage, Discharge Timer and Fault
Length (mm)592
Maximum Battery Charging Current8A
ModelFinch PG
Noise ConditionLess than 60dB @ 1 Meter
Noise LevelLess than 58dB & 1 Meter
Nominal Input Voltage400/415V (3 ph +N)
Output ConnectionTerminals
Output Current Crest Ration3:1 (max)
Output Frequency Range ( Batt)50 Hz +- 0.1 Hz or 60 Hz +- 0.1 Hz
Output Transfer TimeZero
Output Voltage200/208/220/230/240VAC
Output Voltage Regulation'+/-1%
Output Waveform ( Batt. Mode)Pure Sinewave
Output- Voltage400/415V (3ph+N)
Overload105%- 100%: 10 Mins 110%-130%: 1 Min 130%> : 3 Sec
Power Factor>= 0.99 at 100% Load
Waveform ( Battery Mode)Pure Sinewave
Weight28 Kgs
Width (mm)250